  net2 ac-dc series data sheet mcd10012 rev. 1.0, 23-aug-07 page 1 of 5 www.power-one.com features ? rohs lead-solder exemption ? 400w output power with currents over 100 amps ? 85% efficiency (typical) ? 5-output construction ? isolated v2 and v3 outputs ? standby output of 5v @ 2a ? fits 1u chassis height constraints ? no minimum load requirement ? active current-share capabilities with redundant capabilities on the four main outputs ? patented high-efficiency design ? meets european power factor requirements ? excellent load transient response ? redundancy without use of oring diode multiple-output model selection ? 400w with 460 lfm forced-air cooling model output adjustment output line load & cross- ripple & noise initial setting voltage range current regulation regulation pk-pk (note 2) accuracy (note 3) v1 +3.3v +5%, -2% 55a 0.6% 1% 50mv +40mv, -10mv net2-4350 (note1) v2 12v +5%, -5% 5a 0.5% 1% 120mv 70mv v3 12v +5%, -5% 5a 0.5% 1% 120mv 70mv v4 +5v +5%, -2% 40a 0.5% 1% 50mv +50mv, -10mv v5 +5.2v sb fixed 2a 0.5% 4% 50mv 110mv v1 +3.3v +5%, -2% 55a 0.6% 1% 50mv +40mv, -10mv NET2-4231 (note1,4) v2 12v +5%, -5% 5a 0.5% 1% 120mv 70mv v3 1.8v +5%, -2% 15a 0.6% 1% 120mv 70mv v4 +2.5v +5%, -2% 55a 0.6% 1% 50mv +30mv, -10mv v5 +5.2v sb fixed 2a 0.5% 4% 50mv 110mv notes: 1) v1 + v2, or v3 + v4 must not exceed 200w. 2) maximum peak-to-peak noise for a 20 mhz bandwidth. 3) initial set points: v1 @ 40a, v2 @ 4a, v3 @ 4a, v4 @ 30a, and v5 @ 1a. 4) consult factory for availability. designed to meet the stringent requirements of today?s high-speed circuitry, power-one?s net2 series is an excellent compact power solution for low-voltage, high-current applications. the net2?s high efficiency is achieved through the use of synchronous rectification and a newly-patented ?soft transition forward converter?. the net2?s rectification method lowers output losses, reduces system cooling requirements (allowing greater power in a smaller package), and eliminates minimum-load requirements. advanced surface-mount design and packing technology reduce the net2?s height to 1.59? (40.3mm) to fit in 1u applications. net2?s high-performance active power factor circuitry meets en61000-3-2 requirements for compliance with european power line harmonic requirements for 2001. a multifunctional output terminal allows connection to #8 ring lugs, 0.25? quick disconnects, cable connectors, and pcb-mounted connectors. description advance product release
net2 ac-dc series data sheet mcd10012 rev. 1.0, 23-aug-07 page 2 of 5 www.power-one.com input specifications parameter conditions/description min typ max units input voltage - ac continuous input range. 85 264 vac input frequency ac input. 47 63 hz hold-up time after last ac line peak at 400 watts. 20 ms input current 85 vac at full rated load. 7.0 a rms input protection non-user serviceable internally located ac input line fuse. inrush surge current internally limited by thermistor. vin = 220 vac, one cycle, 25c. 35 a pk power factor per en61000-3-2 (over the entire input range and above 60w load). 0.95 w/va output specifications parameter conditions/description min typ max units efficiency full rated load, 115 vac. varies with distribution of loads among outputs. 85 % ripple and noise full load, 20 mhz bandwidth. see model selection charts output power with 460 lfm forced-air cooling (25 cfm through the power supply opening), v1+v2+v3+v4+v5: 400 watts v1+v2 or v3+v4: 200 overshoot / undershoot output voltage overshoot/undershoot at turn-on. 3.5 % regulation varies by output. regulation includes: line changes over the specified see model selection charts input range and changes in load between 0% and 100% load. transient response recovery time, to within 1% of initial set point due to a 50% load change in v1/v4/v5: 1 ms the load range of 10 to 100%; 3.5% or 100mv deviation, whichever is greater. v2/v3 0.5 turn-on delay time required for initial output voltage stabilization. 1.5 2 sec turn-on rise time time required for output voltage to rise from 10% to 90%. 20 ms interface signals and internal protection parameter conditions/description min typ max units overvoltage protection overvoltage protection on all outputs except v5. 120 140 % unit latches off when overvoltage is detected. ac input must be recycled to reset. v5 is protected by a 6.2v 5%, 2w zener diode. overload protection fully protected against output overload and short circuit. automatic recovery upon removal of overload condition. all outputs are individually current limited. overtemperature protection power supply shuts down due to excessive internal overtemperature at the output converter?s primary switching transistors. power supply resets automatically upon removal of the overtemperature cause. output good ttl-compatible global output good signal. the signal is active when any of the v1-v4 outputs drop >14% below nominal. source impedance is 1k  . input power fail warning open collector signal. time before regulation dropout due to loss of input 5ms power. may be used as independent psok signal in redundant applications. current share available on all outputs except v5. accuracy of shared current with up 10 % to two parallel units. single wire current share is provided. for paralleling more than two units, consult factory. remote sense available on all outputs except v5. total voltage compensation for cable losses with 500 mv respect to the main output.
net2 ac-dc series data sheet mcd10012 rev. 1.0, 23-aug-07 page 3 of 5 www.power-one.com safety, regulatory, and emi specifications parameter conditions/description min typ max units agency approvals ul60950. net2-4350 approved; NET2-4231 pending csa 22.2, no. 60950-00 (cul). net2-4350 approved; NET2-4231 pending en60950-1 (tv). net2-4350 approved; NET2-4231 pending iec60950-1 net2-4350 approved; NET2-4231 pending dielectric withstand voltage input to output per en60950. 2600 vdc electromagnetic interference fcc cfr title 47 part 15 sub-part b - conducted. b class en55022 / cispr 22 conducted. b esd susceptibility per en61000-4-2, level 4. contact discharge: 10% 8 kv air discharge: 10 radiated susceptibility per en61000-4-3, level 3. frequency 0.8 - 1.0 ghz, 80% am @ 1 khz 10 v/m eft/burst per en61000-4-4, level 3. 2 kv input transient protection per en61000-4-5, class 3. line to line 1 kv line to ground 2 ground leakage ul60950/en60950/csa 6950-00 @254vac 1 ma environmental specifications parameter conditions/description min typ max units altitude operating. 10k asl ft. non-operating. 40k asl ft. operating temperature from 50c to 70c derate each output and total power at 100% load 0 50 c to 50% of rating at 70c. storage temperature -40 85 c temperature coefficient 0c to 70c (after 15-minute warmup). 0.02 0.05 %/c relative humidity non-condensing. 5 95 %rh shock operating: half-sine, 10 3ms duration; one positive and 10 20 g pk one negative shock in each of the three perpendicular axes for a total of 6 shocks. non-operating: half-sine, 10 3ms duration; one positive 30 40 g pk and one negative shock in each of the three perpendicular axes for a total of 6 shocks. vibration operating: logarithmic sweep, 1 octave/min 5-2000-5 hz vertical, lateral, and longitudinal axes; 5-32 hz, 0.02? double amplitude; 32-2000 hz 1 gpk 2000-32 hz 1 gpk 32-5 hz double amplitude. non-operating: random 1 hour/axis, vertical, lateral, and 6.15 grms max longitudinal over 10-2000 hz. mechanical description notes size impact metric mounting m3 x 0.5 mounting inserts: 3 mounting surfaces chassis size 8.25" x 4.50" x 1.59" (209.6mm x 114.3mm x 40.4mm)
net2 ac-dc series data sheet mcd10012 rev. 1.0, 23-aug-07 page 4 of 5 www.power-one.com bottom view 1.588" (40.3) m3 x 0.5 mounting inserts (8) places, 2 pl each side, 4pl on bottom. 0.150" max protrusion of mounting screws into power supply. 0.700" (17.8) 0.375" (9.5) 0.250" (6.4) -1.100" (-27.9) 2.100" (53.3) 7.600" (193) - 0.900" (-22.9) 8.000" (203.2) 4.125" (104.8) 4.500" (114.3) 0.550" (14) 7.600" (193.0) 0.900" (22.9) 0.370" (9.4) 0.331" (8.4) 0.331" (8.4) 0.331" (8.4) 0.331" (8.4) 0.219" (5.6) 0.400" (10.2) 8.250" (209.6) 0 0 0 0 0 0 m m m m m m m m 0.020 note: tolerance ( .xxx = 0.010 unless otherwise specified) note: metric dimensions are shown in brackets + 0.000 - 0.020 high current outputs 0.25" quick disconnect, 12 pl max or #8 lug 4pl, or wickman connector pn: 9100080000 or equiv, 4 pl mechanical drawing
net2 ac-dc series data sheet mcd10012 rev. 1.0, 23-aug-07 page 5 of 5 www.power-one.com net2-4350 NET2-4231 p1 housing 50-37-5113 pins 08-70-1039 p2 housing 50-37-5043 & p4 pins 08-70-1039 p3 housing 39-01-4041 & p5 pins 39-00-0038 input & outputs vo3 output pinout sec.cntl.brd.pinout vo2 output pinout l n g sec.cntl, vo5 vo2 o/p vo1 vo1 rtn vo3 o/p vo4 vo4 rtn j6 j1 vo1 adj vo3 adj vo4 adj vo2 adj vo3 inhibit vo2 inhibit vo1 +r.s. vo1 -r.s. vo2 -r.s. vo4 +r.s. vo2 +r.s. vo4 -r.s. vo3 c.shr. vo2 c.shr. vo1 c.shr. vo4 c.shr. power fail power good inhibit +vo5 -vo5 vo3 -r.s. vo3 +r.s. vo3 rtn vo3 rtn vo3 vo3 vo2 rtn vo2 rtn vo2 vo2 p5 p4 p1 p2 p3 connectors the net2 uses #8-32 screw terminal and/or 0.25? faston connections for outputs 1 and 4, and molex 5264-n series connectors (50-37-5093) for auxiliary outputs and control signals. for the ac input, the net2 uses a molex 41694/2139 (09-50-3051) series connector. nuclear and medical applications - power-one products are not designed, intended for use in, or authorized for use as critical c omponents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written conse nt of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice. note: part numbers are molex; equivalents are acceptable.


▲Up To Search▲   

 
Price & Availability of NET2-4231

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X